- Optional Dual Access Doors – Allow access from either side, expediting care.
- Thermal Performance – Patented dual air curtains reduce radiant heat loss from the infant by warming the inner hood surface. A bi-directional airflow feature helps to minimize temperature fluctuations when the access doors are opened.
- Large Mattress and Dual Probes – The C2000 incubator allows for simultaneous care of twins in the same unit, allowing more incubators for more patients.
- Internal Noise Level less than or equal to 47dBA – Maintains a supportive environment for both patient and caregiver.
- Optional In-bed Scale – Weigh the baby in a warm environment with minimal disturbance.
- 24-hour Data Trends – This unit facilitates record keeping for air and skin temperature, oxygen, humidity, heater power, and weight changes.
Width: 38.0" (99 cm)
Depth: 26.3" (67 cm)
Height: 52.5" - 60" (133.4 to 152.4 cm)
Weight: 198 lbs (90 kg)
Air-Shields Incubator with Fixed Height Stand
Width: 46.8" (119 cm)
Depth: 26.3" (67 cm)
Height: 56" (142 cm)
Weight: 175 lbs (79.5 kg)
Hood Specifications
Mattress tray size: 16" x 32" (40.6 81 cm)
Mattress to hood: 16.25" (41.2 cm)
Access panel opening: 11" (28 cm)
Standard hood includes: 4 port doors; 2 iris ports; front access panel; 3 left and 3 right tubing grommets-front
Mattress tilt: ±12° (±1° C)
Micro air intake filter: 99.9% efficiency
Particle size removal: 0.3 micron
Air mode control range: 20 to 39.0°C
Air mode override: >37.0°C
Air flow velocity across mattress: <10 cm/sec
Skin mode control range: 34.0 to 38.0° C
Skin mode override: >37.0° C
Temperature rise time (at 22°C ambient): <35 minutes
CO2 levels: <0.5% when delivered at 750 ml/min at a point 10 cm above the mattress
Operating noise level in hood: 47 dBA (49 dBA with Servo Controlled Oxygen)
Casters (4 casters, 1 steering): 5" (12.7 cm)
RS-232 output
Controller with LCD with brightness control
Selectable color combinations: white on blue background (default) or yellow on black background
Dual-skin temperature monitoring
6 AC (Mains) outlet
Keypad lock
24 Hour trend of: Air temperature, skin temperature (1 and 2), Relative humidity, Oxygen concentration, Heater power
Environmental Requirements
Operating temperature range: 20°C to 30°C ambient
Storage temperature range: -25°C to 60°C ambient
Operating humidity range: 5% RH to 99% RH, non condensing
Storage humidity range: 0% to 99% RH, non condensing
Operating RH sensor temp. range: 20°C to 41°C
Operating O2 sensor temp. range: 20°C to 41°C
O2 sensor calibration pressure: 600 to 900 mm Hg
Alarms
Temperature (limiting ≤): 38°C for air temp. < 37°C; 40.0° C for air temp. > 37° C
Baby set temperature: ±1° C (or ±0.5° C)
Air set temperature: +1.5° C/-2.5° C
High/Low Skin Temperature Alarms
High/low air temperature
High temperature cut-out
Air probe failure
Skin probe failure/disconnect
Low air flow
Low humidity (humidity option)
Low/high oxygen (±3%) (oxygen option)
Oxygen calibration required (oxygen option)
Oxygen cell difference (oxygen option)
Oxygen solenoid failure (oxygen option)
Scale disconnect (scale option)
Too much weight (scale option)
System Alarms
Controller failure
Sensor module failure
sensor module out of position
Motor failure
Power failure
Heater failure
Sensor disconnected
Key stuck
RETURN POLICY:
- Damaged freight needs to be reported within 24 hours to file a claim.
- No merchandise may be returned without prior written authorization by Victori Medical.
- No NEW merchandise may be returned unless authorization from manufacturer which could result in a restocking fee or no return at all, and customer is responsible for shipping expenses.
- Return period for products is thirty (30) days from delivery or otherwise agreed upon.
- Victori Medical will test returned products returned and can impose a customer fee if the customer misrepresents the condition of the product.
CREDIT AND RETURN SHIPPING GUIDELINES
- Order cancellations (after 24 hours) and returns are charged a 25% restocking fee.
- If the credit or return is Victori Medical's Error, then 100% credit including shipping expenses will be credited.
- Unused goods in original packaging may receive an 75% credit, and customer is responsible for shipping expenses both ways unless otherwise agreed upon.
- Damaged goods will receive credit dependent on the condition of the product, and customer is responsible for shipping expenses.
- No credit will be issued if the item is non-returnable, such as a new product, custom or special order, or in the case that the item is damaged due to improper handling/packaging by the customer.
FREE SHIPPING ON $100 MINIMUM ORDER RESTRICTIONS
- Free shipping applies to qualifying orders over $100 or more
- Because of freight charges, we cannot offer free shipping on hospital beds, exam tables, procedure chairs, stretchers, C-Arms, and surgical tables
- Free shipping includes any FedEx, UPS, & USPS shipping but excludes any LTL freight delivery, liftgate service delivery, inside delivery, and white glove service.
- Free shipping includes all 48 contiguous US states, but excludes Hawaii and Alaska
-
WILL NOT DELIVER INSIDE TO RESIDENTIAL HOMES. YOU WILL NEED TO HAVE YOUR OWN MOVING COMPANY OR HELP. IF NOT, THE ITEM WILL BE DELIVERED TO THE DRIVEWAY.
SHIPPING CHARGES:
Customers are responsible for making sure items can be delivered into or outside of their facility without issue. For example, can a 53’ foot truck access your building? Failure to accommodate delivery can result in items not being delivered, additional fees, or return of equipment.
Basic Shipping Charge is for dock to dock shipping and/or liftgate service shipping. The items shipping dock to dock and/or liftgate are skidded/palletized items. It doesn’t not include inside delivery.
Residential shipping charge is for customer’s needing delivery in a residential area.
Inside delivery is for customer’s needing their purchase delivered inside the building. The item(s) will be delivered into the lobby only. They not be delivered into rooms/suites, elevators, or stairs.
Customers are responsible for disposing of packing materials.
If you are needing white glove delivery, please contact us directly at orders@tasimed.com.
WARRANTY:
For new products, please refer to the manufacturer's website for details. Below is Victori Medical's Limited Warranty information:This product has been refurbished and tested to the highest quality standards by Victori Medical, LLC. This Limited Warranty offered by Victori Medical, LLC covers defects in material or workmanship. This warranty extends to the original purchaser only and is nontransferable. The warranty begins the day the equipment is received. Please inspect your item(s) upon delivery. Any unauthorized service providers working on our equipment within the warranty period will void the warranty!
Victori Medical, LLC warrants this product against defects in material or workmanship as follows: A. Victori Medical, LLC will replace at no charge for parts only or, at its option,replace any product or part of the product that proves defective because of improper workmanship and/or material, under normal installation, use, service and maintenance. If Victori Medical, LLC is unable to provide a replacement and repair is not practical or cannot be made in a timely fashion, Victori Medical, LLC may elect to refund the purchase price in exchange for the return of the product.
Our warranty periods are 90 days parts and labor from the documented date of receipt. Extended warranties (up to 1 year from date of purchase) are available.
Our warranties do not cover any problem that is caused by: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.
Our limited warranties are void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).
Victori Medical, LLC will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling warranty statement included with your product and you follow proper return procedure. To request warranty service, you will need to provide: 1. The invoice or other evidence of the date and place of purchase. 2. A description of the problem. 3. Contact our Customer Service Department to receive a Return Authorization Number (RMA#)
When warranty service is completed, any repaired or replacement product or part will be returned to you postage prepaid.
Victori Medical, LLC SHALL NOT BE LIABLE TO THE PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY (INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY).
The laws of the State of Illinois, USA, govern our warranties. It gives you specific legal rights, and you mayalso have other rights that vary from state to state. Our warranties do not affect any additional rights consumers have under laws in their jurisdictions governing the sale of consumer goods. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the limitations or exclusions in our warranty statements may not apply. You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson-Moss Warranty Act.