Skip to content
(847) 419-0123 | *FREE SHIPPING ON ALL US ORDERS OVER $100* | WE PRICE MATCH!
Victori Medical is a leading medical and surgical equipment provider that supplies used, professionally refurbished and new equipment!
*FREE SHIPPING ON ALL US ORDERS OVER $100*
WE PRICE MATCH!
Victori Medical is a leading medical and surgical equipment provider that supplies used, professionally refurbished and new equipment!

Mortara Instrument 802.11 ECG with AM12 Patient Cable & Modem Communications 200 Record Storage

SKU: BUR280-81X
Original price $4,565.00 - Original price $4,565.00
Original price
$4,565.00
$4,565.00 - $4,565.00
Current price $4,565.00
CONDITION: FACTORY NEW
ESTIMATED DELIVERY: SHIPS IN 5-7 BUSINESS DAYS
SHIPPING: FREE SHIPPING
The ELI 280 Electrocardiograph elevates your workflow with robust features packed into a portable, touchscreen device. Handle high-volume demands in both acute care and physician offices with its intuitive interface. Navigate menus effortlessly on the 10.1" display, expedite patient data entry, and confirm electrode connections at a glance. Backed by 30 years of expertise and the VERITAS® algorithm, the ELI 280 delivers uncompromised ECG performance and confident interpretations.
Key Features:
  • 10.1", high-resolution, color touchscreen presents all 12 leads of data simultaneously
  • Best 10 feature captures the cleanest 10 seconds of ECG data from memory, which can help reduce the need for repeat ECGs
  • VERITAS algorithm uses gender-specific, adult and pediatric criteria for interpretations
  • Acquire ECGs on pediatric patients with the ability to filter ECGs to see higher heart rates, tighter QRS signals and diverse signals often seen in pediatric patients
  • Widescreen ECG display helps improve navigation, data entry and electrode connection verification
  • Optional wireless data acquisition increases workspace flexibility so you can move freely around the room
  • Supports pacemaker spike detection with 40,000 sps/channel data capture
  • Includes hook-up confirmation by detection and display of lead reversals
  • 1k sps/channel capture for signal assessment during analysis, display and printing
  • Reduce data entry errors by scanning patients wristband to download their information from your EMR
  • DICOM (optional) allows ECG data to be stored and shared with other devices/software
  • Enhanced Security (optional) protects patient data with encryption, user authentication, and audit trails
  • Previously branded as Welch Allyn, Mortara, Burdick and is now Baxter

 

Instrument Type: Multi-lead electrocardiograph
Input Channels: Simultaneous acquisition of all 12 leads
Standard Leads Acquired: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Waveform Display: Backlit, 10.1" high-resolution color LCD
Digital Sampling Rate: 40,000 s/sec/channel used for pacemaker spike detection; 1000 s/sec/channel used for recording and analysis
Optional Functions: VERITAS resting ECG interpretation algorithm with age and gender specific criteria; connectivity with bidirectional communication
Paper: Perforated Z-fold thermal paper, A4 or 8.5 x 11" wide, 250 sheets
Thermal Printer: Computer-controlled dot array; 1 dot/ms horizontal, 8 dots/mm vertical
Thermal Printer Speeds: 5, 10, 25, or 50 mm/s
Gain Settings: 5, 10, or 20 mm/mV
Report Print Formats: Standard or Cabrera: 3+1, 3+3, 6, 6+6, or 12 channel
Rhythm Print Formats: 3, 6, 8, or 12 channel with configurable lead groups
Frequency Response: 0.05 to 300 Hz
Filters: High-performance baseline filter; AC interference filter 50/60 Hz; low-pass filters 40 Hz, 150 Hz, or 300 Hz
A/D Conversion: 20 bits (1.17 microvolt LSB)
Device Classification: Class I, Type CF defibrillation-proof applied parts
ECG Storage: Internal storage up to 200 ECGs
Weight: 12.5 lbs. (5.68 kg) including battery (without paper)
Dimensions: 17.5 x 15.5 x 4.5” (44.45 x 39.37 x 11.43 cm)
Power: Universal AC power supply (100-240 VAC at 50/60 Hz) 110 VA; internal rechargeable battery
ELI 280 Unit
10 Lead Patient Cable (AM12/USB Wired Patient Cable)
1 Pack of Paper
1 Pack of Electrodes (100 Count)
10 Alligator Clips
User Manual

RETURN POLICY:

  • Damaged freight needs to be reported within 24 hours to file a claim.
  • No merchandise may be returned without prior written authorization by Victori Medical.
  • No NEW merchandise may be returned unless authorization from manufacturer which could result in a restocking fee or no return at all, and customer is responsible for shipping expenses.
  • Return period for products is thirty (30) days from delivery or otherwise agreed upon.
  • Victori Medical will test returned products returned and can impose a customer fee if the customer misrepresents the condition of the product.

CREDIT AND RETURN SHIPPING GUIDELINES

  • Order cancellations (after 24 hours) and returns are charged a 25% restocking fee.
  • If the credit or return is Victori Medical's Error, then 100% credit including shipping expenses will be credited.
  • Unused goods in original packaging may receive an 75% credit, and customer is responsible for shipping expenses both ways unless otherwise agreed upon.
  • Damaged goods will receive credit dependent on the condition of the product, and customer is responsible for shipping expenses.
  • No credit will be issued if the item is non-returnable, such as a new product, custom or special order, or in the case that the item is damaged due to improper handling/packaging by the customer.

FREE SHIPPING ON $100 MINIMUM ORDER RESTRICTIONS

  • Free shipping applies to qualifying orders over $100 or more
  • Because of freight charges, we cannot offer free shipping on hospital beds, exam tables, procedure chairs, stretchers, C-Arms, and surgical tables
  • Free shipping includes any FedEx, UPS, & USPS shipping but excludes any LTL freight delivery, liftgate service delivery, inside delivery, and white glove service.
  • Free shipping includes all 48 contiguous US states, but excludes Hawaii and Alaska
  • WILL NOT DELIVER INSIDE TO RESIDENTIAL HOMES. YOU WILL NEED TO HAVE YOUR OWN MOVING COMPANY OR HELP. IF NOT, THE ITEM WILL BE DELIVERED TO THE DRIVEWAY.

SHIPPING CHARGES:

Customers are responsible for making sure items can be delivered into or outside of their facility without issue. For example, can a 53’ foot truck access your building? Failure to accommodate delivery can result in items not being delivered, additional fees, or return of equipment.

Basic Shipping Charge is for dock to dock shipping and/or liftgate service shipping. The items shipping dock to dock and/or liftgate are skidded/palletized items. It doesn’t not include inside delivery.

Residential shipping charge is for customer’s needing delivery in a residential area.

Inside delivery is for customer’s needing their purchase delivered inside the building. The item(s) will be delivered into the lobby only. They not be delivered into rooms/suites, elevators, or stairs.

Customers are responsible for disposing of packing materials.

If you are needing white glove delivery, please contact us directly at orders@tasimed.com.

WARRANTY:

For new products, please refer to the manufacturer's website for details. Below is Victori Medical's Limited Warranty information:

This product has been refurbished and tested to the highest quality standards by Victori Medical, LLC. This Limited Warranty offered by Victori Medical, LLC covers defects in material or workmanship. This warranty extends to the original purchaser only and is nontransferable. The warranty begins the day the equipment is received. Please inspect your item(s) upon delivery. Any unauthorized service providers working on our equipment within the warranty period will void the warranty!

Victori Medical, LLC warrants this product against defects in material or workmanship as follows: A. Victori Medical, LLC will replace at no charge for parts only or, at its option,replace any product or part of the product that proves defective because of improper workmanship and/or material, under normal installation, use, service and maintenance. If Victori Medical, LLC is unable to provide a replacement and repair is not practical or cannot be made in a timely fashion, Victori Medical, LLC may elect to refund the purchase price in exchange for the return of the product.

Our warranty periods are 90 days parts and labor from the documented date of receipt. Extended warranties (up to 1 year from date of purchase) are available.

Our warranties do not cover any problem that is caused by: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.

Our limited warranties are void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).

Victori Medical, LLC will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling warranty statement included with your product and you follow proper return procedure. To request warranty service, you will need to provide: 1. The invoice or other evidence of the date and place of purchase. 2. A description of the problem. 3. Contact our Customer Service Department to receive a Return Authorization Number (RMA#)

When warranty service is completed, any repaired or replacement product or part will be returned to you postage prepaid.

Victori Medical, LLC SHALL NOT BE LIABLE TO THE PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY (INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY).

The laws of the State of Illinois, USA, govern our warranties. It gives you specific legal rights, and you mayalso have other rights that vary from state to state. Our warranties do not affect any additional rights consumers have under laws in their jurisdictions governing the sale of consumer goods. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the limitations or exclusions in our warranty statements may not apply. You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson-Moss Warranty Act.

×

Please wait...

Make An Offer

Descriptive image text
Descriptive image text
×

Offerly Support

Don't fret! This pop up only shows up in Shopify Editor Mode. Offerly could not find your add to cart button! This can happen for one of the following reasons:

    1. This product is sold out.
      To solve this please navigate to a different product!

    2. Your Theme is custom or uses different text for the "Add to Cart" button.
      If this is the case, please contact support and we will add support for your theme!